Rumah> Blog> GYTY53 Fiber Optic Cable/Computer Cable/Data Cable/Communication Cable/Audio Cable/Connector

GYTY53 Fiber Optic Cable/Computer Cable/Data Cable/Communication Cable/Audio Cable/Connector

April 08, 2024
Wire Core Material: Glasses
Certification: CE, ISO, RoHS
Model: GYTY53 Fiber Optic Cable
Brand: Hanli
Allowed Tensile Strength: >10000n
Trademark: hanxin
Transport Package: 1000/2000/3000m
Specification: 4-48C
Origin: Zhejiang
HS Code: 8544700000
Wire Core Material: Glasses
Certification: CE, ISO, RoHS
Model: GYTY53 Fiber Optic Cable
Brand: Hanli
Allowed Tensile Strength: >10000n
Trademark: hanxin
Transport Package: 1000/2000/3000m
Specification: 4-48C
Origin: Zhejiang
HS Code: 8544700000
Product Description
Central Loose Tube GYTY53 Fiber Optic Cable
    Application
This cable is ideal for in long distance and interoffice communication in strong current zone, as well as power transmission system. The built in suspension stranded rope provides high tensile strength, enabling the cable suited for large span installation, resulting in time and installation cost savings. The suspension wire, being an integral part of the cable, is easily available for gripping, fastening and pulling. This cable is featured of its lightness, low dispersion and high tensile strength.
    Description
The cable consists of 5 to 36 fibers containing tubes or fi llers stranded in up to 3 layers around a central strength member and bound under a PE jacket. Each jelly fi lled tube contains 4 -12 fi bers. Solid or stranded steel wire coated with polyethylene is usually used as central strength member. Fiber glass reinforced plastics (FRP) will be used as central strength member if non metallic construction is required. Either aramid yarn or fi ber glass is wound around the tube to provide physical protection and tensile strength. Water blocking materials are fi lled in the interstice of the cable core, core wrapping layer/water blocking tape. The cable can be jacketed with either PE, PVC or LSZH though PE is the preferred option for water protection purpose. For direct burial, steel wire armour or corrugated steel tape armour is applied with an optional inner jacket of either PVC or PE. An optional Aluminium moisture tape can be incorporated under the jacket for water blocking and shielding purpose. Cable cores are connected with the suspension wires by PE sheath to form a fi gure "8" shape. An optional ripcord is located under the jacket to facilitate jacket removal.
 Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
2-24 303.0 203.36 9.1*21.5 0.36*0.85 2670/600 890/200
36-72 332.0 222.82 11.1*23.5 0.44*0.93 2670/600 890/200
96-144 417.0 279.87 15.9*28.3 0.63*1.12 2670/600 890/200

   Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
   Mechanical Properties
Minimum Bending Radius:
 
Maximum Compressive Load: 4000N for unarmored cables;
Under installation: 20×OD
 
6000N for armoured cables
During operation 0×OD for unarmoured cables Repeated Impact: 4.4 N.m (J)

 
20×OD for armoured cables Twist (Torsion): 180×10 times, 125×OD
Temperature Range:
 
Cyclic Flexing: 25 cycles for armoured cables.
Operating Temperature Range: -40ºC(-40ºF) to +70ºC(+158ºF)
 
100 cycles for unarmoured cables.
Storage Temperature Range: -50ºC(-58ºF) to +70ºC(+158ºF) Crush Resistance: 220N/cm (125lb/in)
   Fiber Compliance
Temperature Cycling 
Tensile Strength 
Crush 
Impact 
Repeated Bending 
Torsion 
Kink 
Cable Bend 
Cool Bend
IEC60794-1-2-F2 
IEC60794-1-2-E1A
IEC60794-1-2-E3 
IEC60794-1-2-E4 
IEC60794-1-2-E6 
IEC60794-1-2-E7 
IEC60794-1-2-E10 
IEC60794-1-2-E11 
IEC60794-1-2-E11
   Safety Compliance
General Purpose Grade Flammability Test: OFN (UL1581)
Riser Grade Flammability Test: OFNR/FT4 (UL1666)
Plenum Grade Flammability Test: OFNP/FT6 (UL 910)
FRPVC Grade Flammability Test: IEC60332-1
LSZH Grade Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2
LSFROH Grade  Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2 
Flammability Test: IEC60332-1 & IEC 60332-3C/A
FR Grade Fire Resistance Test : IEC 60331 / BS 6387 CW


 GYTS Optical Fiber Cable/Computer Cable/Data Cable/Communication Cable/Audio Cable/Connector

Welcome to visit our factory and  get our samples.
Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you.


Choose us, won't make you disappointed:
1.6years manufactory experience
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)

Contact person: Susan Zhao  
Mob:0086-13282823725
Website: http://hanlicable.com   http://kuayuecable.en.made-in-china.com
Product Description
Central Loose Tube GYTY53 Fiber Optic Cable
    Application
This cable is ideal for in long distance and interoffice communication in strong current zone, as well as power transmission system. The built in suspension stranded rope provides high tensile strength, enabling the cable suited for large span installation, resulting in time and installation cost savings. The suspension wire, being an integral part of the cable, is easily available for gripping, fastening and pulling. This cable is featured of its lightness, low dispersion and high tensile strength.
    Description
The cable consists of 5 to 36 fibers containing tubes or fi llers stranded in up to 3 layers around a central strength member and bound under a PE jacket. Each jelly fi lled tube contains 4 -12 fi bers. Solid or stranded steel wire coated with polyethylene is usually used as central strength member. Fiber glass reinforced plastics (FRP) will be used as central strength member if non metallic construction is required. Either aramid yarn or fi ber glass is wound around the tube to provide physical protection and tensile strength. Water blocking materials are fi lled in the interstice of the cable core, core wrapping layer/water blocking tape. The cable can be jacketed with either PE, PVC or LSZH though PE is the preferred option for water protection purpose. For direct burial, steel wire armour or corrugated steel tape armour is applied with an optional inner jacket of either PVC or PE. An optional Aluminium moisture tape can be incorporated under the jacket for water blocking and shielding purpose. Cable cores are connected with the suspension wires by PE sheath to form a fi gure "8" shape. An optional ripcord is located under the jacket to facilitate jacket removal.
 Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
2-24 303.0 203.36 9.1*21.5 0.36*0.85 2670/600 890/200
36-72 332.0 222.82 11.1*23.5 0.44*0.93 2670/600 890/200
96-144 417.0 279.87 15.9*28.3 0.63*1.12 2670/600 890/200

   Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
   Mechanical Properties
Minimum Bending Radius:
 
Maximum Compressive Load: 4000N for unarmored cables;
Under installation: 20×OD
 
6000N for armoured cables
During operation 0×OD for unarmoured cables Repeated Impact: 4.4 N.m (J)

 
20×OD for armoured cables Twist (Torsion): 180×10 times, 125×OD
Temperature Range:
 
Cyclic Flexing: 25 cycles for armoured cables.
Operating Temperature Range: -40ºC(-40ºF) to +70ºC(+158ºF)
 
100 cycles for unarmoured cables.
Storage Temperature Range: -50ºC(-58ºF) to +70ºC(+158ºF) Crush Resistance: 220N/cm (125lb/in)
   Fiber Compliance
Temperature Cycling 
Tensile Strength 
Crush 
Impact 
Repeated Bending 
Torsion 
Kink 
Cable Bend 
Cool Bend
IEC60794-1-2-F2 
IEC60794-1-2-E1A
IEC60794-1-2-E3 
IEC60794-1-2-E4 
IEC60794-1-2-E6 
IEC60794-1-2-E7 
IEC60794-1-2-E10 
IEC60794-1-2-E11 
IEC60794-1-2-E11
   Safety Compliance
General Purpose Grade Flammability Test: OFN (UL1581)
Riser Grade Flammability Test: OFNR/FT4 (UL1666)
Plenum Grade Flammability Test: OFNP/FT6 (UL 910)
FRPVC Grade Flammability Test: IEC60332-1
LSZH Grade Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2
LSFROH Grade  Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2 
Flammability Test: IEC60332-1 & IEC 60332-3C/A
FR Grade Fire Resistance Test : IEC 60331 / BS 6387 CW


 GYTS Optical Fiber Cable/Computer Cable/Data Cable/Communication Cable/Audio Cable/Connector

Welcome to visit our factory and  get our samples.
Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you.


Choose us, won't make you disappointed:
1.6years manufactory experience
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days)

Contact person: Susan Zhao  
Mob:0086-13282823725
Website: http://hanlicable.com   http://kuayuecable.en.made-in-china.com
Hubungi kami

Author:

Mr. Annry-wang

Phone/WhatsApp:

+86 13713335011

Produk populer
You may also like
Related Categories

Email ke pemasok ini

Subjek:
Email:
Pesan:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Kirim